BDI - Digital RF Power Measurement System
DPS-100D
P.O.A
* Ex GST. Check with us for Discounts and the latest Trade pricing!
Broadcast Devices - Digital RF Power Measurement System
This system is suitable for measuring analog or digital RF signals with accuracy
within +/- 5% of reading. Use the DPS-100D as a standalone power monitor/antenna protection system
or use more than one DPS-100D to create a monitor system for master antenna applications or for
complete RF facility site monitoring.
The DPS-100D is part of a larger family of site monitoring
products available from Broadcast Devices, Inc.
Specifications:
- Frequency Range: Sensor: 50 MHz to 860 MHz
- Power Range: Sensor: Linear Range -40dbm to +10dbm. No
damage to +23dbm
Directional Coupler: See table below
Coupler Common Features :
- Coupler Sizes available: Type N, DIN, 7/8”, 1-5/8”, 3-1/8”, 4-1/16”, 6-1/8”
- Coupler Loss: -60 dB
- Through Line VSWR: 1.03:1 or better
- Coupled Port Directivity: 30 dB or better
- Frequency Range: 50 to 860 MHz
- Through Line Impedance: 50 ohms
- Measurement Type: True RMS – Suitable for CW, multi carrier and high crest
factor digital RF signals such as COFDM, 8 VSB, DVB, etc.
- Accuracy: +/- 5% of reading.
- Dynamic Range: 40db Linear Dynamic Range. Measurements
possible over 50db with reduced accuracy.
- Power Measurement Range: 0 – 1 Mega watt– Coupler Line Size Dependent
- Measurement Capabilities: Forward and Reflected RF Power,
Transmission line temperature (Deg F / Deg C
user selectable)
1 – External Temperature and line pressure
sensors.
6 – User configurable closure inputs.
(typically patch panels, lock-out/tag-out)
- Integrated Digital Display: 2 Line x 16 character LCD display of Fwd/Ref
RF Power, Temperature (x2), Line Pressure
Dedicated Icons for VSWR fault, Alert Status, Communications Status, RF Power High/Low thresholds, DC
power input status and LAN connection status.
- Communications Interfaces: Ethernet, RS-485, CAN, USB
- Network Protocols: SNMP, SMTP, TCP/IP, UDP, SNTP, HTTP
- Remote Control Interface:
- 2 – Configurable VDC proportional power outputs,
- 2 – Form C configurable interlock/status relays/On/off
- 2 – Configurable External GP inputs for fault reset
- 12 Position Terminal Block: 6 – Configurable General Purpose Inputs for lock
out tag out, patch panel, external interlock strings,
etc.
- Ext. Temperature Sensor Input: 3 – Position terminal block mates with BDI TMP-100 T
Temperature Sensor
- Ext. Pressure Sensor Input: 3 Position terminal block mates with BDI PSW-100 Pressure
Sensor
- DC Input: 12VDC Power Supply Available from BDI or phantom
powered by BDI SWP Series Supervisory Chassis